Sysc messages, Sysc-1001, Sysc-1002 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual
Page 940: Sysc-1004
918
Fabric OS Message Reference
53-1003140-01
SYSC-1001
5
SYSC Messages
SYSC-1001
Message
Failed to run error message (string)>. Message Type FFDC | LOG Severity CRITICAL Probable Cause Indicates that one of the programs would not run on the system during the boot sequence. Recommended Action If the message is reported during a reboot after new firmware has been loaded, try reloading the If the message persists, there may be a conflict between the two versions of firmware or the nonvolatile If the message persists, execute the supportFtp command (as needed) to set up automatic FTP SYSC-1002 Message Switch bring-up timed out. Message Type FFDC | LOG Severity CRITICAL Probable Cause Indicates that the system timed out during a reboot or failover sequence, waiting for one or more Recommended Action The switch is in an inconsistent state and can be corrected only by a reboot or power cycle. Before SYSC-1004 Message Daemon Message Type LOG Severity INFO Probable Cause Indicates that a terminated daemon is restarted by the system automatically. Recommended Action Execute the supportSave command to gather troubleshooting data. No further action is required.
firmware using the firmwareDownload command.
storage may be corrupted.
transfers; then execute the supportSave command and contact your switch service provider.
programs to register with system services or to fail over to active status.
rebooting the chassis, record the firmware version on the switch or control processor (CP) and run the
haDump command. If this is a dual-CP switch, gather the output from the CP in which this log message
appeared.