Auth-1032, Auth-1033, Auth-1034 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual
Page 186
164
Fabric OS Message Reference
53-1003140-01
AUTH-1032
5
Recommended
Action
Reset the secret value using the secAuthSecret command.
Reinitialize authentication using the portDisable and portEnable commands or the switchDisable and
switchEnable commands.
If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.
AUTH-1032
Message
Failed to generate for length>, error code Message Type LOG Severity ERROR Probable Cause Indicates that the authentication process failed to generate specific data (challenge, nonce, or response A nonce is a single-use, usually random value used in authentication protocols to prevent replay attacks. Usually this problem is transient. The authentication may fail. Recommended Action Reinitialize authentication using the portDisable and portEnable commands or the switchDisable and If the message persists, execute the supportFtp command (as needed) to set up automatic FTP AUTH-1033 Message Disable port Message Type LOG Severity ERROR Probable Cause Indicates that an entity was not configured in the Switch Connection Control (SCC) policy and tried to Recommended Action Add World Wide Name (WWN) of the entity to the SCC policy and reinitialize authentication by using the AUTH-1034 Message Failed to validate name number>. Message Type LOG Severity ERROR Probable Cause Indicates that the specified entity name in the payload is not in the correct format.
data) for an authentication payload. This usually relates to internal failure.
switchEnable commands.
transfers; then execute the supportSave command and contact your switch service provider.
connect to the port.
portDisable and portEnable commands or the switchDisable and switchEnable commands.