Zone-1007, Zone-1010, Zone-1013 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual
Page 987
Fabric OS Message Reference
965
53-1003140-01
ZONE-1007
5
Recommended
Action
No action is required.
ZONE-1007
Message
Ioctl (
(
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that frame filter logic reported a failure during the specified I/O Control (IOCTL) call. This is
usually a programming error when adding CAM entries before the filter setup.
Recommended
Action
Avoid this problem in the following ways:
•
Avoid having too many hosts zoned with a set of target devices at a single port.
•
Avoid having too many zones directed at a single port group on the switch.
ZONE-1010
Message
Duplicate entries in zone (
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that there are duplicate entries in the specified zone object. This message occurs only when
enabling a zone configuration.
Recommended
Action
Check the members of the zone using the cfgShow command. Delete the duplicate member using the
zoneRemove command.
ZONE-1013
Message
QuickLoop not supported.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the QuickLoop feature is not supported in the current version of Fabric OS. QuickLoop
zones are not supported in Fabric OS version 4.x or later. Even if the QuickLoop zoning configuration is
enabled on the switch, it will not be supported.
Recommended
Action
Edit the zone database to remove the QuickLoop zoning definition in the effective configuration.