Fcr-1054, Fcr-1055, Fcr-1056 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual
Page 416
394
Fabric OS Message Reference
53-1003140-01
FCR-1054
5
FCR-1054
Message
Port size>); valid ILS size is Message Type LOG Severity WARNING Probable Cause Indicates that an internal link service (ILS) IU of invalid size was received from the switch on the other Recommended Action Check the error message log on the other switch using the errShow command for additional messages. Check for a faulty cable or deteriorated small form-factor pluggable (SFP). Replace the cable or the SFP Run the portLogDumpPort command on both the receiving and transmitting ports. Run the fabStatsShow command on the transmitting switch. If the message persists, collect switch information using the supportSave command, and contact your FCR-1055 Message Switch with domain ID Message Type LOG Severity INFO Probable Cause Indicates that a switch that does not support backbone-to-edge routing was detected in the backbone. Recommended Action No action is required if backbone-to-edge routing is not required. Otherwise, replace the switch with one FCR-1056 Message Switch edge imports. Message Type LOG Severity INFO Probable Cause Indicates that a switch that does not support backbone-to-edge routing is running in the MetaSAN. Recommended Action No action is required if backbone-to-edge routing is not needed. Otherwise, replace the switch with one
end of the link.
if necessary.
switch service provider.
Edge-to-edge routing will work, but backbone-to-edge routing may fail.
that supports backbone-to-edge routing.
that supports backbone-to-edge routing.