beautypg.com

Swch-1010, Swch-1011, Swch-1012 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual

Page 933

background image

Fabric OS Message Reference

911

53-1003140-01

SWCH-1010

5

SWCH-1010

Message

Trunk Area (TA) enabled on slot with switch not in PID format 1. TA

enabled ports will be persistently disabled.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the blade is enabled with the port configuration that had Trunk Area enabled previously.

Recommended

Action

Disable Trunk Area on ports that had Trunk Area enabled previously. Refer to the Fabric OS
Administrator's Guide
for more information.

SWCH-1011

Message

HA out of sync: Stby CP (ver=) doesn't support Trunk Area

functionality. (active ver=, TA enabled on sw=<'1' if Trunk

Area ports exist; Otherwise '0'>).

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the standby control processor (CP) does not support Trunk Area functionality, but the
switch has some ports with Trunk Area enabled.

Recommended

Action

Load a firmware version on standby CP that supports Trunk Area functionality by using the
firmwareDownload command.

SWCH-1012

Message

Trunk Area () has been enabled for one or more ports.

Message Type

AUDIT | LOG

Class

CFG

Severity

INFO

Probable Cause

Indicates that a Trunk Area has been enabled for one or more ports and the configuration file has been
updated.

Recommended

Action

No action is required.