Changing the severity level of swEventTrap

1

To change the severity level of swEventTrap, perform the following steps.

1. Log in to the switch as admin.

2. Execute the snmpConfig

--

set mibCapability command to configure MIBs interactively. All the

supported MIBs and associated traps are displayed. You can change the DesiredSeverity for
swEventTrap to 1 (Critical), 2 (Error), 3 (Warning), or 4 (Informational). The default value is 0.

switch:admin> snmpconfig --set mibcapability

FE-MIB: YES

SW-MIB: YES

FA-MIB: YES

FICON-MIB: YES

HA-MIB: YES

FCIP-MIB: YES

ISCSI-MIB: YES

IF-MIB: YES

BD-MIB: YES

SW-TRAP: YES

swFault: YES

swSensorScn: YES

swFCPortScn: YES

swEventTrap: YES

DesiredSeverity:Informational

swFabricWatchTrap: YES

DesiredSeverity:None

swTrackChangesTrap: YES

swIPv6ChangeTrap: YES

swPmgrEventTrap: YES

swFabricReconfigTrap: YES

swFabricSegmentTrap: YES

swExtTrap: NO

swStateChangeTrap: NO

swPortMoveTrap: NO

swBrcdGenericTrap: YES

...

SW-TRAP (yes, y, no, n): [yes]

swFault (yes, y, no, n): [yes]

swSensorScn (yes, y, no, n): [yes]

swFCPortScn (yes, y, no, n): [yes]

swEventTrap (yes, y, no, n): [yes]

DesiredSeverity: (0..4) [4] 3

swFabricWatchTrap (yes, y, no, n): [yes]

DesiredSeverity: (0..4) [0] 2

swTrackChangesTrap (yes, y, no, n): [yes]

swIPv6ChangeTrap (yes, y, no, n): [yes]

swPmgrEventTrap (yes, y, no, n): [yes]

[...]

3. Execute the snmpConfig

--

show mibCapability command to verify the severity level of

swEventTrap.

switch:admin> snmpconfig --show mibcapability

FE-MIB: YES

SW-MIB: YES

FA-MIB: YES

FICON-MIB: YES

HA-MIB: YES

FCIP-MIB: YES

ISCSI-MIB: YES