Bl-1003, Bl-1004, Bl-1006 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual
Page 200
178
Fabric OS Message Reference
53-1003140-01
BL-1003
5
BL-1003
Message
Faulting blade in slot
Message Type
FFDC | LOG
Severity
CRITICAL
Probable Cause
Indicates a faulty blade in the specified slot.
Recommended
Action
Make sure that the blade is seated correctly.
If the blade is seated correctly, execute the diagPost command to make sure that Power-On Self-Test
(POST) is enabled; then power cycle the blade using the slotPowerOff and slotPowerOn commands or
have the blade's ejector switch cycled to run POST and verify that the blade does not have any hardware
problems.
If the message persists, replace the blade.
BL-1004
Message
Suppressing blade fault in slot
Message Type
FFDC | LOG
Severity
CRITICAL
Probable Cause
Indicates that the specified blade experienced a failure but was not faulted due to a user setting.
Recommended
Action
Execute the diagPost command to make sure that Power-On Self-Test (POST) is enabled; then power
cycle the blade using the slotPowerOff and slotPowerOn commands or have the blade's ejector switch
cycled to run POST and verify that the blade does not have any hardware problems.
If the message persists, replace the blade.
BL-1006
Message
Blade
failure.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the errors (mostly synchronization errors) on the specified blade are harmless. Probably,
the standby control processor (CP) blade connected to the active CP blade has experienced transitory
problems.
Recommended
Action
Execute the haShow command to verify that the standby CP is healthy. If the problem persists, remove
and reinstall the faulty blade.