TRCE-1010
Message
Traced fails to start.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the trace daemon (traced), which is used for transferring the trace files has failed to start.
The trace capability within the switch is unaffected. The system automatically restarts the traced facility
after a brief delay.
Recommended
Action
Reboot the CP (dual-CP system) or restart the switch.
If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.
TRCE-1011
Message
Trace dump manually transferred to target ' slot the trace dump is transferred> ': Message Type LOG Severity INFO Probable Cause Indicates that the trace dump files were transferred manually to the specified slot. Recommended Action No action is required. TRCE-1012 Message The system was unable to retrieve trace information from slot interface module on which the attempt was made>. Message Type LOG Severity WARNING Probable Cause Indicates that the system was unable to retrieve trace information from the specified slot because there is Recommended Action Check that the interface module is enabled and retry the command. If the interface module is already
no communication between the main system and the slot.
enabled, execute the supportSave command and contact your switch service provider.