Fabric os system messages, Ag messages, Ag-1001 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual
Page 153: Ag-1002, Chapter 5, Chapter
Fabric OS Message Reference
131
53-1003140-01
Chapter
5
Fabric OS System Messages
AG Messages
AG-1001
Message
N_Port ID virtualization (NPIV) is not supported by fabric port connected to port
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the N_Port ID virtualization (NPIV) capability is not supported by the fabric port to which
the Access Gateway is connected.
Recommended
Action
•
Execute the portCfgNpivPort command to enable NPIV capability on the port connected to the
Access Gateway.
•
Some blades and ports in a switch may not support NPIV. NPIV functionality cannot be enabled
on such ports and they will not respond to NPIV requests. Refer to the Access Gateway
Administrator's Guide for specific AG-compatibility requirements.
•
On non-Brocade switches, refer to the manufacturer's documentation to determine whether
the switch supports NPIV and how to enable NPIV on these types of switches.
AG-1002
Message
Unable to find alternate N_Port during failover for N_Port
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that no other N_Port is configured or the fabric was unstable during failover.
Recommended
Action
Check whether an alternate N_Port is configured using the portCfgShow command.
If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.