180
Fabric OS Message Reference
53-1003140-01
BL-1010
5
Recommended
Action
Make sure that the blade is seated correctly.
If the blade is seated correctly, execute the diagPost command to make sure that Power-On Self-Test
(POST) is enabled; then power cycle the blade using the slotPowerOff and slotPowerOn commands or
have the blade's ejector switch cycled to run POST and verify that the blade does not have any hardware
problems.
If the message persists, replace the blade.
BL-1010
Message
Blade in slot
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that a failover occurred while some hardware changes (such as changing the domain ID) were
being made on the previously active control processor (CP).
Recommended
Action
No action is required. This blade has been reinitialized. Because reinitializing a blade is a disruptive
operation and can stop I/O traffic, you may need to stop and restart the traffic during this process.
BL-1011
Message
Busy with emb-port int. for chip
Message Type
FFDC | LOG
Severity
CRITICAL
Probable Cause
Indicates that too many interrupts in the embedded port caused the specified chip to be disabled. The
probable cause is too many abnormal frames; the chip is disabled to prevent the control processor (CP)
from becoming too busy.
Recommended
Action
Make sure to capture the console output during this process.
Check for a faulty cable, small form-factor pluggable (SFP) transceiver, or device attached to the
specified port.
On a bladed switch, execute the diagPost command to make sure that Power-On Self-Test (POST) is
enabled; then power cycle the blade using the slotPowerOff and slotPowerOn commands or have the
blade's ejector switch cycled to run POST and verify that the blade does not have any hardware
problems.
On a non-bladed switch, reboot or power cycle the switch.
If the message persists, replace the blade or the (non-bladed) switch.