background image

Fabric OS Message Reference

217

53-1003140-01

C3-1015

5

C3-1015

Message

Port re-initialized due to Link Reset failure on internal Port S

number>,P().

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the specified port is re-initialized due to link reset failure.

Recommended

Action

When this error is observed persistently, power cycle the specified blade using the slotPowerOff and
slotPowerOn commands. If the problem persists, replace the blade.

C3-1016

Message

Port is faulted due to port re-initialization failure on internal Port S

number>,P() with reason .

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the specified port failed due to port re-initialization failure.

Recommended

Action

When this error is observed persistently, power cycle the specified blade using the slotPowerOff and
slotPowerOn commands. If the problem persists, replace the blade.

C3-1017

Message

Blade in Slot- failed due to unavailability of ports in the internal

trunk.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the specified blade failed because of the unavailability of the ports in the internal trunk.

Recommended

Action

When this error is observed persistently, power cycle the specified blade using the slotPowerOff and
slotPowerOn commands. If the problem persists, replace the blade.