Swch messages, Swch-1001, Swch-1002 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual
Page 930: Swch-1003

908
Fabric OS Message Reference
53-1003140-01
SWCH-1001
5
SWCH Messages
SWCH-1001
Message
Switch is not in ready state - Switch enable failed, switch status= 0x status>, c_flags = 0x Message Type LOG Severity ERROR Probable Cause Indicates that the switch is enabled before it is ready. Recommended Action If the message persists, execute the supportFtp command (as needed) to set up automatic FTP SWCH-1002 Message Security violation: Unauthorized device port Message Type LOG Severity INFO Probable Cause Indicates that the specified device is not present in the authorized profile list. Recommended Action Verify that the device is authorized to log in to the switch. If the device is authorized, execute the SWCH-1003 Message Slot ENABLED but Not Ready during recovery, disabling slot = value>). Message Type LOG Severity ERROR Probable Cause Indicates that the slot state has been detected as inconsistent during failover or recovery. Recommended Action For a bladed switch, execute the slotPowerOff and slotPowerOn commands to power cycle the blade. For a non-bladed switch, reboot or power cycle the switch.
transfers; then execute the supportSave command and contact your switch service provider.
secPolicyDump command to verify whether the World Wide Name (WWN) of the specified device is
listed. If it is not listed, execute the secPolicyAdd command to add this device to an existing policy.