beautypg.com

Em-1014, Em-1015, Em-1016 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual

Page 325

background image

Fabric OS Message Reference

303

53-1003140-01

EM-1014

5

EM-1014

Message

Unable to read sensor on ().

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the environmental monitor (EM) was unable to access the sensors on the specified
field-replaceable unit (FRU).

Recommended

Action

Reseat the FRU. If the problem persists, replace the FRU.

EM-1015

Message

Warm recovery failed ().

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that a problem was discovered when performing consistency checks during a warm boot.

Recommended

Action

Monitor the switch. If the problem persists, restart or power cycle the switch.

EM-1016

Message

Cold recovery failed ().

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that a problem was discovered when performing consistency checks during a cold boot.

Recommended

Action

Monitor the switch.

If the problem persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.