beautypg.com

Fabr-1051, Fabr-1052, Fabr-1053 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual

Page 376

background image

354

Fabric OS Message Reference

53-1003140-01

FABR-1051

5

FABR-1051

Message

D-Port test failed for slot and port .

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the D_Port test failed for the given slot and port due to one of the following reasons:

The small form-factor pluggable (SFP) fault detected by electrical loopback test failure.

The cable fault detected by optical loopback test failure.

An application-specific integrated circuit (ASIC) issue detected by link traffic test failure.

Recommended

Action

Replace the faulty SFPs, cables, or blade.

FABR-1052

Message

The configured port speed is invalid. Persistently disabling port

being disabled>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the configured speed for the specified port is invalid.

Recommended

Action

Execute the portCfgSpeed command to change the port speed.

FABR-1053

Message

The switch is disabled due to an inconsistency found in the interop config

parameters.

Message Type

LOG

Severity

CRITICAL

Probable Cause

Indicates that the configuration keys have interopmode parameters such as switch.interopMode and
switch.mcdtFabricmode set.

Recommended

Action

Execute the interopmode command to reset the parameters.