Sulb-1010, Sulb-1011 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual
Page 919
Fabric OS Message Reference
897
53-1003140-01
SULB-1010
5
Recommended
Action
Run the firmwareDownloadStatus command for more information.
In a modular switch, when the firmwareDownload command fails, the command will synchronize the
firmware on the two partitions of each CP by starting a firmware commit operation. Wait until this
operation completes (about 10 minutes) before attempting another firmware download.
In a modular switch, when the firmwareDownload command fails, the two CPs may end up with
different versions of firmware and they may not gain high availability (HA) sync. In this case, run the
firmwareDownload -s command to upgrade the firmware on the standby CP to the same version as the
active CP. Then retry the firmwareDownload command to download the desired version of firmware
onto the CPs.
Refer to the Fabric OS Troubleshooting Guide for troubleshooting information.
SULB-1010
Message
Firmwarecommit failed (status=0x
Message Type
AUDIT | LOG
Class
FIRMWARE
Severity
INFO
Probable Cause
Indicates that the firmwareCommit command failed. The error code provides debugging information.
Recommended
Action
If the failure is caused by an inconsistent filesystem, contact your switch service provider.
SULB-1011
Message
Firmwaredownload command failed.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the firmwareDownload command failed. The error string value indicates the reason for
failure.
SUS_PEER_RESTORE_BEGIN
0x30
SUS_SBY_RESTORE_BEGIN
0x31
SUS_PEER_FWC_BEGIN
0x32
SUS_PEER_FS_CHECK1
0x33
SUS_FINISH
0x34
SUS_COMMIT
0x35
TABLE 9
Upgrade state and code value
Upgrade state
Code