background image

Fabric OS Message Reference

755

53-1003140-01

SEC-1028

5

SEC-1028

Message

No name is specified.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates a corruption occurred during the distribution of the security database. This can occur only when
the primary fabric configuration server (FCS) distributes the security database to the other switches in
the fabric, and then local validation finds the error in the security database. This is a rare occurrence.

Recommended

Action

Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in
the ready state. If a switch is in the error state, the database may not be correctly updated for that
specific switch.

SEC-1029

Message

Invalid character in .

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates a corruption occurred during the distribution of the security database. This can occur only when
the primary fabric configuration server (FCS) distributes the security database to the other switches in
the fabric, and then local validation finds the error in the security database. This is a rare occurrence.

Recommended

Action

Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in
the ready state. If a switch is in the error state, the database may not be correctly updated for that
specific switch.

SEC-1030

Message

The length of the name is invalid.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates a corruption occurred during the distribution of the security database. This can occur only when
the primary fabric configuration server (FCS) distributes the security database to the other switches in
the fabric, and then local validation finds the error in the security database. This is a rare occurrence.

Recommended

Action

Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in
the ready state. If a switch is in the error state, the database may not be correctly updated for that
specific switch.