Fabr-1024, Fabr-1029, Fabr-1030 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual
Page 369
Fabric OS Message Reference
347
53-1003140-01
FABR-1024
5
FABR-1024
Message
Initializing fabric size limit timer
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the fabric size has exceeded the limit set by your value-line switches. Value-line switches
have a limited fabric size (for example, a specified limit on the number of domains). This value is defined
by your specific value-line license key. The fabric size has exceeded this specified limit. The grace period
timer has been initialized. If the grace period is complete and the size of the fabric is still outside the
specified limit, Web Tools is disabled.
Recommended
Action
Bring the fabric size within the licensed limits. Either a full fabric license must be added or the size of the
fabric must be changed to within the licensed limit. Contact your switch provider to obtain a full fabric
license.
FABR-1029
Message
Port flow control mode>). Message Type LOG Severity INFO Probable Cause Indicates that a different flow control mode, as described in the message, is negotiated with the port at • VC_RDY mode: Virtual-channel flow control mode. This is a proprietary protocol. • R_RDY mode: Receiver-ready flow control mode. This is the Fibre Channel standard protocol, • DUAL_CR mode: Dual-credit flow control mode. In both of the previous modes, the buffer Recommended Action No action is required. FABR-1030 Message fabric: Domain Message Type LOG Severity INFO Probable Cause Indicates that the domain ID has changed.
the other end of the link. The flow control is a mechanism of throttling the transmitter port to avoid buffer
overrun at the receiving port. There are three types of flow control modes:
that uses R_RDY primitive for flow control.
credits are fixed, based on the port configuration information. In this mode, the buffer credits
are negotiated as part of exchange link parameter (ELP) exchange. This mode also uses the
R_RDY primitive for flow control.