beautypg.com

Spc-3008, Spc-3009, Spc-3010 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual

Page 873

background image

Fabric OS Message Reference

851

53-1003140-01

SPC-3008

5

SPC-3008

Message

S, : SP crypto got READY

notification.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the key application (KPD) within the CryptoModule of the encryption engine has been
started.

Recommended

Action

No action is required.

SPC-3009

Message

S, : FIPS certificate

mismatch, certificate: .

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the Federal Information Protection Standard (FIPS) certificate within the CryptoModule
does not match that of the node.

Recommended

Action

Zeroize the encryption engine (after backing up any needed primary or secondary KEK), then execute
the cryptocfg --initEE and cryptocfg --regEE commands.

SPC-3010

Message

S, : SEK integrity failure

during initialization.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates the CryptoModule internal Secret Encryption Key has been corrupted or has not been
initialized.

Recommended

Action

Execute the cryptocfg --initEE and cryptocfg --regEE commands.