Plat messages, Plat-1000, Plat-1001 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual
Page 731: Plat-1002
Fabric OS Message Reference
709
53-1003140-01
PLAT-1000
5
PLAT Messages
PLAT-1000
Message
Message Type
FFDC | LOG
Severity
CRITICAL
Probable Cause
Indicates that nonrecoverable peripheral component interconnect (PCI) errors have been detected.
Recommended
Action
The system will be faulted and may automatically reboot.
If the system does not reboot automatically, reboot the system manually using the reboot command.
Execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the
supportSave command and contact your switch service provider.
PLAT-1001
Message
CP
reset may occur).
Message Type
LOG
Severity
INFO
Probable Cause
Indicates the other control processor (CP) is being reset. This message is typically generated by a CP
that is in the process of becoming the active CP. Note that in certain circumstances a CP may experience
a double reset and reboot twice. A CP can recover automatically even if it has rebooted twice.
Recommended
Action
No action is required.
PLAT-1002
Message
CP
Fence 0x register. Contents are platform-specific> CP Error 0x are platform-specific>. Message Type LOG Severity CRITICAL Probable Cause Indicates that the control processor (CP) cannot access the inter-integrated circuit (I2C) subsystem Recommended Action Reboot the CP if it does not reboot automatically. Reseat the CP if rebooting does not solve the problem.
because of an error condition or because of being fenced or isolated from the I2C bus.
If the problem persists, replace the CP.