beautypg.com

Ag-1009, Ag-1010, Ag-1011 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual

Page 156

background image

134

Fabric OS Message Reference

53-1003140-01

AG-1009

5

AG-1009

Message

Sending FLOGI failed on N_Port .

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that there was a failure sending a Fabric Login (FLOGI) request from the Access Gateway to
the fabric switch.

Recommended

Action

Check the configuration of the fabric switch connected to the Access Gateway.

If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.

AG-1010

Message

Sending PLOGI failed on N_Port .

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that there was a failure sending an N_Port Login (PLOGI) request from the Access Gateway to
the fabric switch.

Recommended

Action

Check the configuration of the fabric switch connected to the Access Gateway.

If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.

AG-1011

Message

Sending FDISC failed on N_Port .

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that there was a failure sending a discover F_Port service parameter request from the Access
Gateway to the fabric switch.

Recommended

Action

Check the configuration of the fabric switch connected to the Access Gateway.

If the message persists, execute the supportFtp command (as needed) to set up automatic FTP