Ag-1009, Ag-1010, Ag-1011 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual
Page 156
134
Fabric OS Message Reference
53-1003140-01
AG-1009
5
AG-1009
Message
Sending FLOGI failed on N_Port
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that there was a failure sending a Fabric Login (FLOGI) request from the Access Gateway to
the fabric switch.
Recommended
Action
Check the configuration of the fabric switch connected to the Access Gateway.
If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.
AG-1010
Message
Sending PLOGI failed on N_Port
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that there was a failure sending an N_Port Login (PLOGI) request from the Access Gateway to
the fabric switch.
Recommended
Action
Check the configuration of the fabric switch connected to the Access Gateway.
If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.
AG-1011
Message
Sending FDISC failed on N_Port
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that there was a failure sending a discover F_Port service parameter request from the Access
Gateway to the fabric switch.
Recommended
Action
Check the configuration of the fabric switch connected to the Access Gateway.
If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.