beautypg.com

Rcs-1010, Rcs-1011, Rcs-1012 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual

Page 759

background image

Fabric OS Message Reference

737

53-1003140-01

RCS-1010

5

RCS-1010

Message

Domain is RCS-incapable. Disabled

E_Port(s) connected to this domain.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the specified remote domain is RCS-incapable, or the RCS-capable information could not
be retrieved for the specified remote domain due to some potential routing issues.

Recommended

Action

Run the rcsInfoShow command to view RCS capability of the switch.

Investigate for routing issue or check the cabling, and re-enable the disabled E_Ports to attempt another
exchange of RCS-capable information.

RCS-1011

Message

Remote domain is RCS-incapable. Configure this domain as

RCS-capable.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the specified remote domain is RCS-incapable, or the RCS-capable information could not
be retrieved for the specified remote domain due to some potential routing issues.

Recommended

Action

Run the rcsInfoShow command to view RCS capability of the switch.

Investigate for routing issue or check the cabling, and re-enable the disabled E_Ports to attempt another
exchange of RCS-capable information.

RCS-1012

Message

Local domain is RCS incapable (ForceDisabled is

is RCS capable or not>), hence reject the RCS_INFO request from domain

number>.

Message Type

LOG | FFDC

Severity

WARNING

Probable Cause

Indicates that the specified domain is RCS-incapable.

Recommended

Action

Execute the supportSave command and contact your switch service provider.