Message
Standby CP is not healthy, device level>. Message Type FFDC | LOG Severity CRITICAL Probable Cause Indicates that a standby control processor (CP) device error is reported by the high availability manager The active CP will continue to function normally. Because the standby CP is not healthy, non-disruptive Recommended Action Restart the standby CP blade by ejecting the card and reseating it. If the problem persists, replace the HAM-1002 Message Standby CP is healthy. Message Type LOG Severity INFO Probable Cause Indicates that all standby control processor (CP) devices monitored by the high availability manager Recommended Action No action is required. HAM-1004 Message Processor rebooted - Message Type LOG Severity INFO Probable Cause Indicates that the switch has been restarted because of a user action or an error. The switch restart can • Hafailover • Reset
(HAM) health monitor, with the specified device and severity level. The severity level can be critical,
major, or minor.
failover is not possible.
standby CP.
(HAM) health monitor reported no error.
be initiated by the firmwareDownload, fastBoot, haFailover, and reboot commands. Some examples
of errors that may initiate this message are hardware errors, software errors, compact flash errors, or
memory errors. The Reboot Reason variable can be one of the following: