beautypg.com

Fcr-1060, Fcr-1061, Fcr-1062 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual

Page 418

background image

396

Fabric OS Message Reference

53-1003140-01

FCR-1060

5

FCR-1060

Message

EX_Port() has an incompatible configuration setting.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that virtual channel (VC) Link Init is enabled on the local switch and the remote switch is
negotiating in R_RDY mode. The fabric might not form properly.

Recommended

Action

Check the configuration on the local switch using the portCfgShow command to verify that the VC Link
Init is disabled, if the remote switch is configured in R_RDY mode or only capable of R_RDY mode.

VC_RDY mode: Virtual channel flow control mode. This is a proprietary protocol.

R_RDY mode: Receiver-ready flow control mode. This is the Fibre Channel standard protocol,
that uses R_RDY primitive for flow control.

FCR-1061

Message

Backbone fabric created on port .

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that a backbone fabric was built on the specified port.

Recommended

Action

No action is required.

FCR-1062

Message

Port disabled, system only supports EX/VEX_ports.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the maximum number of supported EX_Ports or VEX_Ports was exceeded. To enable the
specified port, disable any other operational port and then re-enable the port.

Recommended

Action

No action is required.