Zone messages, Zone-1002, Zone-1003 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual
Page 986: Zone-1004
964
Fabric OS Message Reference
53-1003140-01
ZONE-1002
5
ZONE Messages
ZONE-1002
Message
WWN zoneTypeCheck or zoneGroupCheck warning( number>). Message Type LOG Severity WARNING Probable Cause Indicates that a zone filter or zone group check failure occurred. The frame filter logic reported a failure Recommended Action If the problem persists, execute the supportFtp command (as needed) to set up automatic FTP ZONE-1003 Message zone( Message Type LOG Severity WARNING Probable Cause Indicates that the port zone member that is targeted for the local switch contains a nonexistent port. The Recommended Action Edit the zone database and change the port number to a viable value in the effective configuration. ZONE-1004 Message Base PID: 0x changed to Session-based HARD Zoning. Message Type LOG Severity INFO Probable Cause Indicates that the zoning enforcement has changed to session-based hard zoning due to one of the • The zone has a mix of WWN and domain,index (D,I) members. • The Source Identifier (S_ID) list of the hardware-enforced zoning exceeded the S_ID limit.
when creating or adding the zone groups during port login (PLOGI) trap processing. This message
usually indicates problems when adding the content-addressable memory (CAM) entries before the filter
setup.
transfers; then execute the supportSave command and contact your switch service provider.
specified port number in the effective zoning configuration (displayed in the error message) is out of
range.
following conditions: