Bl-1037, Bl-1038, Bl-1039 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual
Page 212
190
Fabric OS Message Reference
53-1003140-01
BL-1037
5
BL-1037
Message
Faulting chip in slot =
due to BE/BI port fault.
Message Type
LOG
Severity
CRITICAL
Probable Cause
Indicates that all ports on the chip have been disabled due to a fault on the chip.
Recommended
Action
Make sure that the blade is seated correctly.
If the blade is seated correctly, execute the diagPost command to make sure that Power-On Self-Test
(POST) is enabled; then power cycle the blade using the slotPowerOff and slotPowerOn commands or
have the blade's ejector switch cycled to run POST and verify that the blade does not have any hardware
problems.
Additional blade fault messages precede and follow this error, providing more information. Refer to other
error messages for recommended action.
If the message persists, replace the blade.
BL-1038
Message
Inconsistent FPGA image version detected, please reboot the switch for recovery.
Message Type
LOG
Severity
CRITICAL
Probable Cause
Indicates that the field-programmable gate array (FPGA) image version is incompatible with the software
version.
Recommended
Action
Reboot the switch. If the message persists, replace the switch.
BL-1039
Message
Inconsistent FPGA image version detected, faulting the blade in slot number>. Message Type LOG Severity CRITICAL Probable Cause Indicates that the field-programmable gate array (FPGA) image version is incompatible with the software Recommended Action Power cycle the blade using the slotPowerOff and slotPowerOn commands. If the message persists, replace the blade.
version.