Sec-1116, Sec-1117, Sec-1118 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual
Page 802
780
Fabric OS Message Reference
53-1003140-01
SEC-1116
5
SEC-1116
Message
Fail to commit failover.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates a corruption occurred during the distribution of the security database. This can only occur when
the primary fabric configuration server (FCS) distributes the security database to the other switches in
the fabric, and then local validation finds the error in the security database. This is a rare occurrence.
Recommended
Action
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in
the ready state. If a switch is in the error state, the database may not be correctly updated for that
specific switch.
SEC-1117
Message
Fail to set .
Message Type
LOG
Severity
INFO
Probable Cause
Indicates the switch failed to save the data received by the primary fabric configuration server (FCS)
switch. This data can be an FCS password, a non-FCS password, SNMP data, or multiple user
authentication data.
Recommended
Action
Run the fabricShow command to verify that all switches in the fabric are in the ready state. When all
switches are in the ready state, retry the operation.
SEC-1118
Message
Fail to set SNMP string.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates the SNMP string could not be set. Usually this problem is transient.
Recommended
Action
Retry the command.