Ag-1039, Ag-1040, Ag-1041 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual
Page 166
144
Fabric OS Message Reference
53-1003140-01
AG-1039
5
AG-1039
Message
F_Port
through N_Port
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the specified F_Port was reset because an N_Port went offline and the changes need to be
propagated to all involved devices.
Recommended
Action
No action is required. This port reset was not an error.
AG-1040
Message
PID of the devices connected to Port
was toggled. Check EE monitor
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that N_Port ID virtualization (NPIV) assigns a new port ID (PID) each time the same port is
disabled and then re-enabled. As the PID has changed, the end-to-end (EE) monitors installed with the
previous PID stops functioning.
Recommended
Action
Install new EE monitors with the new PID of the port to be monitored by using the perfAddEEMonitor
command.
AG-1041
Message
Static F_Ports mapped to N_Port
on the N_Port.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that a trunk is enabled on the specified N_Port, and therefore the F_Port static mapping is
disabled.
Recommended
Action
Delete static mapping on the Access Gateway using the ag --staticdel command or disable the trunk on
the N_Port using the switchCfgTrunkPort command.