Fcr-1094, Fcr-1095, Fcr-1096 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual
Page 429
Fabric OS Message Reference
407
53-1003140-01
FCR-1094
5
FCR-1094
Message
No Integrated Routing license present. EX-Port
sharing with other Brocade Native mode fabric(s).
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that an EX_Port has been configured in Brocade Native mode. Device sharing will not occur
with other Brocade Native mode fabrics because the Integrated Routing license is not installed.
Recommended
Action
Install Integrated Routing license if device sharing is needed with other Brocade Native mode fabrics.
FCR-1095
Message
The EX-Port
supported, hence will be disabled next time port is offline and online.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that an EX_Port has been configured in 'McData/Open' mode. Initially after HA failover, the
EX_Port will come up in McDATA mode. Further toggling will disable the port.
Recommended
Action
Remove the 'McData/Open' interop modes in all EX_Ports
FCR-1096
Message
Failed to allocate for
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the authentication process failed because the system is low on memory.
Data type is the payload or structure that failed to get memory.
Operation phase specifies which operation of a particular authentication phase failed.
Recommended
Action
Usually this problem is transient. The authentication may fail.
Reinitialize authentication using the portDisable and portEnable commands or the switchDisable and
switchEnable commands.
If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers;
then run the supportSave command and contact your switch service provider.