Bm-1010, Bm-1053, Bm-1054 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual
Page 224

202
Fabric OS Message Reference
53-1003140-01
BM-1010
5
BM-1010
Message
Resetting port configuration and linkcost for all ports for blade in slot number>. Message Type LOG Severity INFO Probable Cause Indicates the specified blade was detected for the first time after an FC10-6 was previously configured in Recommended Action No action is required. The blade ports are cleared automatically. BM-1053 Message Failed to establish connection between CP and Application Processor. Faulting switch. Message Type LOG | FFDC Severity WARNING Probable Cause Indicates that the control processor (CP) could not establish a connection with the application processor Recommended Action Execute the slotPowerOff and slotPowerOn commands or reseat the affected blade. BM-1054 Message AP firmware firmware>. Auto-leveling AP firmware to match system firmware. Message Type LOG Severity INFO Probable Cause Indicates that the policy of the specified blade is set to auto-level the blade firmware to the system • Blade firmware was detected to be different from the control processor (CP) firmware due to a • The blade was recently inserted and had a different version of the firmware loaded. Recommended Action No action is required. The blade will automatically download the updated firmware.
the same slot. The new blade requires resetting the port configuration and linkcost.
(AP) to communicate.
firmware. This may be due to one of the following reasons:
firmware upgrade.