HAMK-1001
5
HAMK Messages
HAMK-1001
Message
Warm Recovery Failed.
Message Type
LOG | FFDC
Severity
CRITICAL
Probable Cause
Indicates that the switch failed during the warm recovery.
Recommended
Action
This event triggers the switch restart automatically and attempts a cold recovery.
Execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the
supportSave command and contact your switch service provider.
HAMK-1002
Message
Heartbeat down.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the active control processor (CP) blade determined that the standby CP blade is down.
This can be a result of a user-initiated action such as firmware download, the standby CP blade being
reset or removed, or an error in the standby CP blade.
Recommended
Action
Monitor the standby CP blade for a few minutes. If this message is due to a standby CP restart, the
HAMK-1003 message will display after the standby CP is restarted.
If the standby CP does not connect to the active CP after 10 minutes, restart the standby CP blade by
ejecting the blade and reseating it.
HAMK-1003
Message
Heartbeat up.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the active control processor (CP) blade detected the standby CP blade. This means that
the standby CP blade is available to take over in case a failure happens in the active CP blade. Typically,
this message is displayed when the standby CP blade restarts.
Recommended
Action
No action is required.