Swch-1004, Swch-1005, Swch-1006 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual
Page 931
Fabric OS Message Reference
909
53-1003140-01
SWCH-1004
5
SWCH-1004
Message
Blade attach failed during recovery, disabling slot =
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the specified blade has failed during failover or recovery.
Recommended
Action
For a bladed switch, execute the slotPowerOff and slotPowerOn commands to power cycle the blade.
For a non-bladed switch, reboot or power cycle the switch.
SWCH-1005
Message
Diag attach failed during recovery, disabling slot =
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the diagnostic blade attach operation has failed during failover or recovery.
Recommended
Action
For a bladed switch, execute the slotPowerOff and slotPowerOn commands to power cycle the blade.
For a non-bladed switch, reboot or power cycle the switch.
SWCH-1006
Message
HA state out of sync: Standby CP (ver =
NPIV functionality. (active ver =
NPIV devices exist; Otherwise '0'>).
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the standby control processor (CP) does not support N_Port ID Virtualization (NPIV)
functionality, but the switch has some NPIV devices logged in to the fabric.
Recommended
Action
Load a firmware version on a standby CP that supports NPIV functionality using the firmwareDownload
command.