Fabric OS Message Reference

397

53-1003140-01

FCR-1063

5

FCR-1063

Message

Fabric for switch with domain ID: mismatch with local

fabric ID .

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the fabric ID of the switch does not match the local switch.

Recommended

Action

Run the switchShow command to display the fabric ID. Change the fabric ID to match on both ends by
modifying either the local or remote host using the fcrConfigure command.

FCR-1064

Message

Fabric ID of backbone FC-Routers mismatch or overlap.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that either a backbone fabric split and both are connected to a common edge fabric, or the
fabric ID of two backbone fabrics connected to an edge fabric are the same.

Recommended

Action

If the backbone fabric split, merge the fabrics.

If two (or more) backbone fabrics have the same IDs, make the fabric IDs unique using the fcrConfigure
command.

FCR-1065

Message

Fabric on port was assigned two different fabric IDs.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that another port on the switch is connected to the same edge fabric with a different fabric ID
assignment.

Recommended

Action

Change the port fabric ID to the same value as the other ports connected to the edge fabric using the
portCfgExport or portCfgVexport commands.