Ms-1009, Ms-1021, Ms-1022 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual
Page 698
676
Fabric OS Message Reference
53-1003140-01
MS-1009
5
MS-1009
Message
RLIR event. Slot/Port
is 0x
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates a registered link incident record (RLIR) has been generated for one of the actions indicated by
the message value.
The message value can be one of the following:
•
Exceeded bit error rate threshold
•
Loss of signal or synchronization
•
Not operational seq recognized
•
Primitive sequence timeout
•
Unrecognized link incident
Recommended
Action
Persistent RLIR incidents are likely the result of SAN hardware problems such as bad cables or small
form-factor pluggable (SFP) transceivers. If the message persists, replace hardware.
MS-1021
Message
MS WARMBOOT failure(FSS_MS_WARMINIT failed. Reason=
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the Fabric OS state synchronization (FSS) warm recovery failed during the WARM INIT
phase of a reboot.
Recommended
Action
If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.
MS-1022
Message
Management Server Platform Service
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the Management Server (MS) platform service is being activated or deactivated.
Recommended
Action