Fabric OS Message Reference

445

53-1003140-01

FICN-1103

5

FICN-1103

Message

DevTeraIngr:Exceptional Status rcvd on Path=0x

DeviceDomain> state=0x

state> status=0x.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the status (0x0D or 0x05) indicating the device is going down was received from the device
or error status (including Unit Check 0x02) is received from an active emulation device.

Recommended

Action

The device doing down is a normal event during pipelining and not the unit check. If there are associated
I/O error messages with this event, contact your vendor's customer support for assistance.

FICN-1104

Message

DevTeraEgr:Device Ready on Path=0x

DeviceDomain>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates the Teradata device has been initialized and is ready for emulation operations.

Recommended

Action

No action is required.

FICN-1105

Message

DevTeraIng:LRJ received on Path=0x

DeviceDomain> lastCmds=0x

received from the channel for this device> lastStatus=0x

presented to the channel for this device> treating as system reset event.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates a Link Level Reject (LRJ) from a FICON channel indicates that the channel does not have a
path established to the Control Unit.

Recommended

Action

This is normally an unexpected event; contact your vendor's customer support for assistance.