94
2 Mbps Digital Trunk Interface
Feature interactions
Periodic Pulse Metering
Periodic Pulse Metering operates the same for 2 Mbps DTI as for analog
trunks.
Pulsed E and M DTI2 Signaling
Pulsed E&M DTI2 signaling is based on 2 Mbps DTI.
Feature packaging
2 Mbps Digital Trunk Interface (DTI2) package 129.
Feature implementation
Task summary list
The following is a summary of the tasks in this section:
1.
"LD 14 – Create or modify trunk data blocks for DTI2 on a per trunk
basis." (page 94)
2.
"LD 16 – Create or modify DTI2 trunk route data blocks." (page 95)
3.
4.
LD 14 - Create or modify trunk data blocks for DTI2 on a per trunk basis.
Prompt
Response
Description
REQ
NEW CHG
Add, or change
TYPE
a...a
Type of data block.
SICA
(1)-16
Signaling Category table number. The category must already
be defined in LD 73.
Default is 16 if loop type = Japanese Digital Multiplex Interface
(JDMI).
Nortel Communication Server 1000
Features and Services - Book 1 of 6 (A to B)
NN43001-106
01.04
Standard
Release 5.0
27 July 2007