Nortel Networks NN43001-106 User Manual
Page 563
Feature implementation
563
Prompt
Response
Description
BTDD
(BOTH)
INC
Busy Tone Detection Direction:
Both Incoming and outgoing calls (default).
Incoming calls only.
FREQ_0
350 - 655
Frequency of Busy Tone for Frequency 0 of a dual Busy Tone
Detection to be detected in Hz. Valid entries are in multiples
of 5Hz.
FREQ_1
350 - 655
Frequency of Busy Tone for Frequency 1 of a dual Busy Tone
Detection to be detected in Hz. Valid entries are in multiples
of 5Hz.
For a single busy tone FREQ_1 must be set the same as
FREQ_0.
FDLT
10 - 315
Frequency Delta. FDLT gives the tolerance of the tone to be
detected in +/- hertz. Valid entries are in multiples of 5Hz.
For dual Busy Tone Detection on the NT5D31 card, the same
maximum and minimum levels apply to both tones.
FLVL_MAX
0 - 15
Maximum Frequency Tone level to be detected. Valid entries
are in multiples of 5dBm.
For dual Busy Tone Detection on the NT5D31 card, the same
level applies to both tones.
FLVL_MIN
20 - 35
Minimum Frequency Tone level to be detected. Valid entries
are in multiples of 5dBm.
For dual Busy Tone Detection on the NT5D31 card, the same
level applies to both tones.
LD 16 - Configure trunk units and trunk timers in the Route Data Block.
Prompt
Response
Description
REQ
NEW
Add a new data block to the system.
TYPE
RDB
Define a new Route Data Block.
CUST
xx
Customer number, as defined in LD 15
ROUT
Route number
0-511
Range for Large System and CS 1000E system.
0-127
Range for Small System and Media Gateway 1000B.
TKTP
COT
Define trunk type as Central Office.
ICOG
IAO
Incoming and Outgoing trunk.
CNTL
YES
Changes to controls or timers.
Nortel Communication Server 1000
Features and Services - Book 1 of 6 (A to B)
NN43001-106
01.04
Standard
Release 5.0
27 July 2007