Nortel Networks NN43001-106 User Manual
Page 352
352
Attendant Supervisory Console
4.
5.
"LD 15 – Enable/disable an M2250 console using Trunk Group Busy
keys as status keys." (page 353)
LD 15 - Enable/disable feature for an M2250 console with a Console Graphics Module in the
Standard Busy Lamp Field mode.
Prompt
Response
Description
REQ:
CHG
Change existing data.
TYPE:
ATT_DATA
Attendant console options.
CUST
Customer number
0-99
Range for Large System and CS 1000E system.
0-31
Range for Small System and Media Gateway 1000B.
- OPT
(XTG) ITG
Exclude/include Trunk Group Busy Indication.
- SPVC
1-63
0
Attendant number for supervisory console. No supervisory
console.
- - SBLF
(NO) YES
Supervisory lamp field array is not or is to be used to monitor
other attendant consoles.
- ITH1
1-255
Visual indication threshold 1 (number of calls in queue ˇ
S
ITH1 but < ITH2).
- ITH2
2-255
Visual indication threshold 2 (number of calls in queue ˇ
S
ITH2 but < ITH3).
- ITH3
3-255
Visual indication threshold 3 (number of calls in queue ˇ
S
ITH3).
LD 15 - Enable/disable feature for an M2250 console with a Console Graphics Module in the
Enhanced Busy Lamp Field mode.
Prompt
Response
Description
REQ:
CHG
Change existing data.
TYPE:
ATT_DATA
Attendant console options.
CUST
Customer number
0-99
Range for Large System and CS 1000E system.
0-31
Range for Small System and Media Gateway 1000B.
- OPT
(XBL) IBL
Exclude/include Busy Lamp Field or Console Graphics Module.
- - SPVC
1-63
0
Attendant number for supervisory console.
No supervisory console.
- ITH1
1-255
Visual indication threshold 1 (number of calls in queue ˇ
S
ITH1 but < ITH2).
Nortel Communication Server 1000
Features and Services - Book 1 of 6 (A to B)
NN43001-106
01.04
Standard
Release 5.0
27 July 2007