Feature implementation, Task summary list, Feature operation – Nortel Networks NN43001-106 User Manual
Page 124
124
500/2500 Line Disconnect
Feature implementation
Task summary list
The following is a summary of the tasks in this section:
1.
"LD 10 – Allow Line Disconnect Tone for analog (500/2500-type) ports."
(page 124)
2.
"LD 15 – Specify the dial tone timer for analog (500/2500-type) ports."
(page 124)
Note: Feature implementation is the same for both 500/2500 Line
Disconnect and 500/2500 Line Disconnect for Outgoing Calls.
LD 10 - Allow Line Disconnect Tone for analog (500/2500-type) ports.
Prompt
Response
Description
REQ:
NEW CHG
New, or change.
TYPE:
500
Telephone type.
TN
Terminal Number
l s c u
Format for Large System and CS 1000E system,
where l = loop, s = shelf, c = card, u = unit.
c u
Format for Small System, Media Gateway 1000B, and Media
Gateway 1000T, where c = card and u = unit.
CLS
(LDTD) LDTA
(WTA) WTD
(Deny) allow Line Disconnect Tone.
(Allow) deny Warning Tone.
LD 15 - Specify the dial tone timer for analog (500/2500-type) ports.
Prompt
Response
Description
REQ:
NEW CHG
New, or change.
TYPE:
TIM
Timers.
CUST
Customer number
0-99
Range for Large System and CS 1000E system.
0-31
Range for Small System, Media Gateway 1000B, and Media
Gateway 1000T.
...
- LDTT
2-(6)-30
Line Disconnect Tone timer for the 500/2500 port, in seconds.
Feature operation
No specific operating procedures are required to use this feature.
Nortel Communication Server 1000
Features and Services - Book 1 of 6 (A to B)
NN43001-106
01.04
Standard
Release 5.0
27 July 2007
Copyright © 2007, Nortel Networks
.