Nortel Networks NN43001-106 User Manual
Page 556
556
Busy Lamp Field
4.
LD 11 – Activate DN hundreds groups for EBLF for each DN within each
hundreds group.
LD 15 - Define the Busy Lamp Field/Console Graphics Module options in the Customer Data
Block.
Prompt
Response
Description
REQ:
CHG
Change existing data.
TYPE:
ATT_DATA
Attendant console options
CUST
Customer number
0-99
Range for Large System and CS 1000E system.
0-31
Range for Small System and Media Gateway 1000B.
- OPT
(XBL) IBL
(Exclude) include Enhanced Busy Lamp Field.
LD 12 - Identify which attendant consoles have Enhanced Busy Lamp Field on the BLF/CGM.
Prompt
Response
Description
REQ
CHG
Change existing data.
TYPE
2250
Attendant console type.
TN
l s c u
Terminal Number
Format for Large System and CS 1000E system,
where l = loop, s = shelf, c = card, u = unit.
c u
Format for Small System and Media Gateway 1000B where
c = card and u = unit.
EBLF
(BLFD) BLFA
(Deny) allow Enhanced Busy Lamp Field.
When the BLF is configured before the telephones are programmed,
the procedures in LD 10 and LD 11 are not required. As an alternative
to reentering data when the BLF is configured after the telephones, a
SYSLOAD associates the DN with the Hundreds Group (HGRP).
LD 10 - Activate DN hundreds groups for EBLF for each DN within each hundreds group.
Prompt
Response
Description
REQ:
CHG
Change existing data.
TYPE:
500
Telephone type.
TN
l s c u
Terminal Number
Format for Large System and CS 1000E system,
where l = loop, s = shelf, c = card, u = unit.
Nortel Communication Server 1000
Features and Services - Book 1 of 6 (A to B)
NN43001-106
01.04
Standard
Release 5.0
27 July 2007
Copyright © 2007, Nortel Networks
.