Nortel Networks NN43001-106 User Manual
Page 265
Feature operation
265
Table 10 "Summary of possible Break-In situations and actions" (page 265)
is a summary of possible Break-In situations and actions.
Table 10
Summary of possible Break-In situations and actions
Condition of called DN
Action
1. Established call, Call Waiting or Camp-on allowed, Multiple
Appearance DN.
Lockout (if not denied).
Break-In allowed,
connection established.
Connection is made.
2. Attendant dialing on SRC, internal call on SRC, CWT or Camp-on
not available, desired party in conference, Call Forward active on
telephone.
Connection is made for the
attendant only.
3. Tones, ringing, dialing, blocking, Override, Camp-on, Hold, talking
to another attendant, Call Transfer, WTD on undesired party.
Release DEST, wait and
repeat.
4. Make Set Busy, Do not disturb.
Predialing operation
possible.
5. Warning tone denied on desired party, maintenance busy.
Break-In impossible.
6. Station is idle.
Station is rung, station not
affected.
7. Invalid numbers.
Break-In impossible.
8. The previous status was "Allowed" or "Consultation Only". SRC
or DEST indicator was active (’Allowed’) or flashing (’Consultation
Only’).
Undesired party is excluded
and the attendant is talking
to the wanted party.
Nortel Communication Server 1000
Features and Services - Book 1 of 6 (A to B)
NN43001-106
01.04
Standard
Release 5.0
27 July 2007
Copyright © 2007, Nortel Networks
.