Feature implementation, Task summary list – Nortel Networks NN43001-106 User Manual
Page 479
Feature implementation
479
•
Controlled Class of Service (CCOS) package 81
•
Background Terminal (BGD) package 99
•
Automatic Wake Up (AWU) package 102
Flexible Tone and Cadences (FTC) package 125 is required if a special
error tone rather than overflow is desired for Automatic Wake Up. FTC
and Message Intercept (MINT) package 163 is required if a recorded
announcement is desired as confirmation from the system after wake up
timer has been entered. International Supplementary Features (SUPP)
package 131 is required if values other than the default are desired for the
inter-digit timer.
Feature implementation
Task summary list
The following is a summary of the tasks in this section:
1.
LD 15 – Enable Automatic Wake Up in the Customer Data Block.
2.
LD 57 – Configure Flexible Feature Codes for Automatic Call Wake Up.
3.
LD 56 – Set Automatic Wake Up special error tone and configuration
tone.
LD 15 - Enable Automatic Wake Up in the Customer Data Block.
Prompt
Response
Description
REQ:
NEW
CHG
Add new data.
Change existing data.
TYPE:
AWU
Change Automatic Wake Up options.
CUST
Customer number
0-99
Range for Large System and CS 1000E system.
0-31
Range for Small System and Media Gateway 1000B.
- AWU
YES
Enable Automatic Wake Up data.
Nortel Communication Server 1000
Features and Services - Book 1 of 6 (A to B)
NN43001-106
01.04
Standard
Release 5.0
27 July 2007
Copyright © 2007, Nortel Networks
.