beautypg.com

Feature implementation, Task summary list – Nortel Networks NN43001-106 User Manual

Page 479

background image

Feature implementation

479

Controlled Class of Service (CCOS) package 81

Background Terminal (BGD) package 99

Automatic Wake Up (AWU) package 102

Flexible Tone and Cadences (FTC) package 125 is required if a special
error tone rather than overflow is desired for Automatic Wake Up. FTC
and Message Intercept (MINT) package 163 is required if a recorded
announcement is desired as confirmation from the system after wake up
timer has been entered. International Supplementary Features (SUPP)
package 131 is required if values other than the default are desired for the
inter-digit timer.

Feature implementation

Task summary list

The following is a summary of the tasks in this section:

1.

LD 15 – Enable Automatic Wake Up in the Customer Data Block.

2.

LD 57 – Configure Flexible Feature Codes for Automatic Call Wake Up.

3.

LD 56 – Set Automatic Wake Up special error tone and configuration
tone.

LD 15 - Enable Automatic Wake Up in the Customer Data Block.

Prompt

Response

Description

REQ:

NEW
CHG

Add new data.
Change existing data.

TYPE:

AWU

Change Automatic Wake Up options.

CUST

Customer number

0-99

Range for Large System and CS 1000E system.

0-31

Range for Small System and Media Gateway 1000B.

- AWU

YES

Enable Automatic Wake Up data.

Nortel Communication Server 1000

Features and Services - Book 1 of 6 (A to B)

NN43001-106

01.04

Standard

Release 5.0

27 July 2007

Copyright © 2007, Nortel Networks

.