Westermo MR Series User Manual
Page 432
432
6622-3201
Web Interface and Command Line Reference Guide
www.westermo.com
X.21 25-Pin to 15-Pin Crossover Cable – Internal Clock
21.1.4
This is normally the cable to use to connect the Westermo to an X.21 leased line. Use this cable
when the Westermo is the clock source or configured as “internal clock”.
25-way D - Westermo Side
15-way D
13
25
14
1
1
9
15
8
Signal
Pin # (DCE)
Pin # (DTE)
Signal
Frame Ground (Case)
Shield
Shield
Frame Ground (Case)
TxDA
2
4
RxDA
RxDA
3
2
TxDA
CTLA
4
5
INDA
INDA
5
3
CTLA
GND
7
8
GND
CLKB
9
13
CLKB
INDB
13
10
CTLB
TxDB
14
11
RxDB
RxDB
16
9
TxDB
CLKA
17
6
CLKA
CTLB
19
12
INDB
N.B. Frame Ground is optional.