Using text commands – Westermo MR Series User Manual
Page 311
311
6622-3201
Web Interface and Command Line Reference Guide
www.westermo.com
NUI/NUA selection:
If both an NUI and an NUA are included in the call string, this parameter allows the unit to fil-
ter one of these out of the X.25 call request.
Using Text Commands
To configure PAD parameters from the command line use the pad command. To display the settings
for the specified PAD instance enter the command:
pad
where
To change the value of a parameter enter the command:
pad
The parameters and values are:
Parameter
Values
Equivalent Web Parameter
amacro
text
Auto macro
anscug
CUG
Answering CUG
ansnua
NUA
Answering NUA
cingnua
NUA
Calling NUA
coneventsec
number
None - If this parameter is non-zero, it indi cates how long a PAD can
be connected to an ASY port before generating an event
defpak
number
Default packet size
dorest
off, on
Restarts
enqcon
off, on
ENQ on connect
inactevent
number
Inactivity Event Time(s)
inacttim
number
Inactivity timeout (s)
ipaddr
IP address
Remote IP address (XOT only)
Ip_port
number
IP Stream port
ip_stream
off, on
IP Stream mode
iphdr
0,1,2
IP length header: 0=Off 1=On 2=8583 Ascii 4 byte
l2iface
lapb, lapd
Layer 2 interface
l2nb
0,1,2
Layer 2 interface #
lcn
number
LCN
lcnup
off, on
LCN direction
llmode
off, on
Leased line mode
nocalltim
number
No call L2 timeout (s)
nuaimode
0,1,2
NUI/NUA selection
padmode
0,1
PAD mode
profile
1-4, 50, 51,90,91
PAD profile #
prompt
text
PAD prompt
restdel
number
Restart delay (ms)
strip_tspaces
off, on
Strip Trailing Spaces
stxmode
0,1
STX/ETX mode
trig_str
text
Data trigger
Backup Parameters
bakl2iface
lapb, lapd
Layer 2 Interface
bakl2nb
0,1,2
Layer 2 Interface Number
baklcn
number
LCN
baklcnup
0,1
LCN direction