Westermo MR Series User Manual
Page 179
179
6622-3201
Web Interface and Command Line Reference Guide
www.westermo.com
2B->1B delay (s):
This is the time (in seconds) for which the transfer rate must fall below 2B->1B rate before the
secondary B-channel will be deactivated. The default is 60 seconds.
Note:
The following four parameters are only available if you have purchased the AODI software
option. To use AODI you will also have to enable the Always on mode parameter on the
Configure > General page.
D->1B up rate (bytes/s):
When Always on mode is “On”, this is the value (in bytes/s) above which the data transfer rate
must remain for D->1B up delay (s) before the unit will activate a B-channel.
D->1B up delay (s):
When Always on mode is “On”, this is the time (in seconds) for which the data transfer rate
must remain above the specified D->1B rate before the unit will activate a B-channel.
1B->D down rate (bytes/s):
When Always on mode is “On”, this is the value (in bytes/s) below which the data transfer rate
must remain for 1B->1D down delay (s) before the unit will deactivate the B-channel.
1B->D down delay (s):
When Always on mode is “On”, this is the time (in seconds) for which the data transfer rate
must remain below the specified 1B->D rate before the unit will activate a B-channel.