Using Text Commands
To configure VXN parameters via the command line use the vxncommand. To display current set-
tings for VXN enter the following command:
vxn
where
To change the value of a parameter use the command in the format:
vxn
The parameter options and values are:
Parameter
Values
Equivalent Web Parameter
connto
number
Socket connection timeout (s)
debug
off, on
Enable debug output
keepopen
off, on
Keep socket open between trans-
actions
mid
text
Merchant ID
opns
off, on
Enable automatic online PUK nego-
tiation (OPNS)
opns_svc_name
text
OPNS service name
opns_svr_name
text
OPNS server name
pwrinit
off, on
Perform initialisation with server at
power up
retries
number
Retries
sdcto
number
Service discovery timeout (s)
simple
off, on
None
svcip1
IP address, URL
Primary host name
svcip2
IP address, URL
Secondary host name
svcname
text
Service name
svcport1
number
Primary port
svcport2
number
Secondary port
syncto
number
Key Synchronisation timeout (s)
tid
text
Terminal ID
tranto
number
Transaction timeout (s)
For example, to set the number of retries to 5 you would enter: