&C DCD Control

17.4

The AT&C command is used to configure the way in which the unit controls the DCD signal to the
terminal. There are three options:

&C0 DCD is always On

&C1 DCD is On only when an ISDN connection has been established (Layer 2 is UP)

&C2 DCD is always Off

&C3 DCD is normally On but pulses low for a time in 10 msec units determined by S register 10.

&F Load Factory Settings

17.5

The AT&F command is used to load a pre-defined default set of S-register and AT command settings
(the default profile). These are: E1, V1, &C1, &K1, &D2, S0=0, S2=43 All other values are set to 0.

&R CTS Control

17.6

The AT&R command is used to configure the way in which the unit controls the CTS signal to the
terminal. There are three options: &R0 CTS is always On &R1 CTS follows RTS. The delay between
RTS changing and CTS changing is set in AT regis ter 56 in multiples of 10msec &R2 CTS is always
Off

&V View Profi les

17.7

The AT&V command displays a list of the current AT command and S register values, and the set-
tings for the two stored profiles. For example:

at&v

CURRENT PROFILE:

&c1 &d2 &k1 &s1 &r0 e1 q0 v1 &y0

S0=0 S2=43 S12=50 S31=3 S45=5

STORED PROFILE 0:

&c1 &d2 &k1 &s1 &r0 e1 q0 v1

S0=0 S2=43 S12=50 S31=3 S45=5

STORED PROFILE 1:

&c1 &d2 &k1 &s1 &r0 e1 q0 v1

S0=0 S2=43 S12=50 S31=3 S45=5

OK