IP connection settings

The Cell Monitor may be configured to transmit the data it retrieves to a specified TCP/IP
address/port. The parameters are as follows:

IP address:

This parameter specifies an IP address to which the unit will attempt to establish a TCP/IP con-
nection. The TCP/IP port must be specified. Any retrieved data is then transmitted over this con-
nection

.

TCP/IP port:

This parameter specifies the destination TCP/IP port number to be used for the connection. The
recently retrieved Cell Monitor information may be viewed on the following web pages:

Status > W-WAN > Neighbour Cells
Status > W-WAN > Serving Cell
Status > W-WAN > W-WAN Cell Info

Using Text Commands

From the command line, the cellmon command can be used to configure the Cell Monitor. To dis-
play the current settings for the Cell Monitor enter the command:

cellmon 0 ?

To change the value of a parameter use the same command in the format:

cellmon 0

The parameters and values are:

Parameter

Values

Equivalent Web Parameter

att_elog

off, on

Attach event log

emailfrom

text

Email From

emailint

number

Email interval (mins)

emailto

text

Email To

etemplate

filename

Email Template

ipaddr

IP address

IP address

ipport

number

TCP/IP port

mon_int

number

Monitoring interval (s)

mong_on

off, on

GPRS information

moni_on

off, on

Serving cells

monp_on

off, on

Neighbour cells

subject

text

Email subject

For example, to disable monitoring of neighbour cells, enter:

cellmon 0 monp_on off