Using the command line interface

3

Using a Web browser to modify text box or table values in the configuration pages is the simplest
way to configure the unit and this process is described in the next chapter. However, if you do not
have access to a Web browser, the unit can be configured using text commands. These commands
may be entered directly at one of the serial ports or via a Telnet session. Remote configuration is
also possible using Telnet or X.25.

To use the serial ports you will need a PC and some communications software such as HyperTermi-
nal™ (supplied with Windows) or TeraTerm™. The same commands may also be used to configure
the unit remotely via Telnet, X.25 or V.120.

There are several types of text command:

AT Commands & S Registers

AT commands (pronounced “ay tee”) and Special registers (S registers) are supported in order
to maintain compatibility with modems when the unit is used as a modem replacement.

Application Commands

Application commands are specific to Westermo products and are used to control most fea-
tures of the unit when not using the Web interface.

X.3 Commands

These are standard X.3 commands which are used only in X.25 PAD mode

TPAD Commands

These are used only in TPAD mode.

The “AT” Command Interface

3.1

Command Prefi x

3.1.1

The “AT” command prefix is used for those commands that are common to modems. To configure
the unit using AT commands you must first connect it to a suitable asynchronous terminal.

You will first need to set the interface speed/data format for your terminal to 115,200bps, 8 data
bits, no parity and 1 stop bit (these settings can be changed later if necessary).

When your terminal is correctly configured, apply power and wait for the B2 indicator to stop
flashing. Unless you have previously configured the unit to automatically connect to a remote sys-
tem on power-up, it will now be ready to respond to commands from an attached terminal and is in
“command mode”.

Now type “AT” (in upper or lower case), and press [Enter]. The unit should respond with the mes-
sage “OK”. This message is issued after successful completion of each command. If an invalid com-
mand is entered, the unit will respond with the message “ERROR”.

Note:
For consistency AT commands are shown in upper case throughout this guide.

If there is no response, check that the serial cable is properly connected and that your terminal or
PC communications software is correctly configured before trying again.

If you have local command echo enabled on your terminal, you may see the AT command displayed
as “AATT”. If this happens you may use the “ATE0” command (which will appear as “AATTEE00”),
to prevent the unit from providing command echo. After this command has been entered, further
com mands will be displayed without the echo.

The “AT” command prefix and the commands that follow it can be entered in upper or lower case.
After the prefix, you may enter one or more commands on the same line of up to 40 characters.
When the line is entered, the unit will execute each command in turn.