176

6622-3201

Web Interface and Command Line Reference Guide

www.westermo.com

Debug level:

This parameter is used to control the amount of information contained in debug traces. It can
be set to “Off”, “Low”, “Med” or “High”. Setting the parameter to “Off” disables debug tracing.

Using Text Commands

From the command line, use the ospf command to configure or display the OSPF settings. To display
current settings for OSPF enter the following command:

ospf ?

where is 0.

To change the value of a parameter use the following command:

ospf

The parameters and values are:

Parameter

Values

Equivalent Web Parameter

adj_to

1-2147483647

Adjacency timeout (s)

adv_only

off, on

Advertise routes only

conffile

text

Configuration file

debug

0,1,2,3

Debug level: 0=Off 1=Low 2=Med
3=High

def_hello_int

1-65535

Default ’Hello’ interval (s)

def_metric

1-65535

Default metric

def_prio

0-255

Default priority

def_retran_int

5-3600

Default retransmit interval (s)

def_rtr_dead_time

2-2147483647

Default router dead time (s)

def_spf_delay

1-10

Default SPF delay (s)

def_spf_hold

1-5

Default SPF hold time (s)

def_tx_delay

1-3600

Default transmit delay (s)

enable

off, on

Enable OSPF

fatal_rest

off, on

Restart OSPF after fatal error

id

IP address

ID

ignore_mtu

off, on

Ignore MTU indications

nbr_to

1-2147483647

Neighbour timeout (s)

new_cfg_rest

off, on

Restart OSPF when new config file
loaded

useipsecent

off, on

Use Interface IPsec source IP

For example, to set the Default SPF delay to 5 seconds enter:

ospf 0 def_spf_delay 5