beautypg.com

Westermo MR Series User Manual

Page 102

background image

102

6622-3201

Web Interface and Command Line Reference Guide

www.westermo.com

Max SMS/day:

The value in this field is the maximum number of SMS messages that the unit will generate per
day. This is intended to prevent messages being repeated frequently when you have set the event
trigger level to a low value, i.e. a value that results in many events generating an automated SMS
alarm.

SMS template:

This field contains the name of the template file that will be used to form the basis of any SMS
alarm messages generated by the event logger. The default template is a text file called “EVENT.
SMS” that is stored within the compressed .web file.

You may create alternative templates but you must use the “.SMS” file extension and store the
files in the normal file directory. If you create a new template with the name “EVENT.SMS”, this
will take precedence over the pre-defined “EVENT.SMS” template.

SMS trigger priority: / #2 / #3

This is the lowest priority event code that will generate an SMS alert message. For example, if
this value is set to 6, only events with a priority of 6 or higher will trigger an automated SMS
alert. To disable SMS alerts set this value to 0.

SMS destination: / #2 / #3

This is the destination phone number for SMS alert messages including the international dialling
code but no “+” prefix or leading 0’s.